Implementing point-of-care MRI at Christ Hospital • Sept. 8th, 5pm ET Register Now

×

Swoop® Portable MR Imaging System

Sequences

Swoop Sequences

We invite you to learn more about Swoop T1, T2, FLAIR, and DWI sequences and view some real-world clinical cases from our numerous global collaborators.

System Part Number(s): 950-11001-03, 950-11001-04, 950-11001-05

T1-Weighted

Resolution: 1.6 × 1.6 × 5 mm

Acquisition type; orientations: 3D; Axial, Sagittal, Coronal

Kspace trajectory: Cartesian, weighted coverage

Image reconstruction: Noise suppression, advanced reconstruction, phase-sensitive parallel imaging reconstruction, navigator drift correction

Post-processing: Geometric distortion correction, intensity correction, advanced denoising

T1

T2-Weighted

Resolution: 1.5 × 1.5 × 5 mm

Acquisition type; orientations: 3D; Axial, Sagittal, Coronal

Kspace trajectory: Cartesian, weighted coverage

Image reconstruction: Noise suppression, advanced reconstruction, phase-sensitive parallel imaging reconstruction, navigator drift correction

Post-processing: Geometric distortion correction, intensity correction, advanced denoising

T2

Fluid-Attenuated Inversion Recovery (FLAIR)

Resolution: 1.6 × 1.6 × 5 mm

Acquisition type; orientations: 3D; Axial, Sagittal, Coronal

Kspace trajectory: Cartesian, weighted coverage

Image reconstruction: Noise suppression, advanced reconstruction, phase-sensitive parallel imaging reconstruction, navigator drift correction

Post-processing: Geometric distortion correction, intensity correction, advanced denoising

FLAIR

Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) Maps

Resolution: 2.4 × 2.4 × 6 mm

Acquisition type; orientations: 3D; Axial

Associated options: ADC mapping, b-value = 900 s/mm2

Kspace trajectory: Cartesian, weighted coverage

Image reconstruction: Noise suppression, NUFFT, conjugate gradient SENSE reconstruction, navigator phase correction, navigator drift correction, motion rejection and rescanning.

Post-processing: Geometric distortion correction, intensity correction

DWI
DWI+ADC

Learn More

click to read about The Clinical and Business Value of Portable Point‑of‑Care MRI - opens in new window
{disply_title}
White Paper

The Clinical and Business Value of Portable Point‑of‑Care MRI

click to read about Clinical Use Cases for the Hyperfine Swoop® Portable MR Imaging System - opens in new window
{disply_title}
White Paper

Clinical Use Cases for the Hyperfine Swoop® Portable MR Imaging System

click to read about Details and Specs - opens in new window
{disply_title}
Link

Details and Specs

Review Swoop® system details and specifications.

click to read about FAQs - opens in new window
{disply_title}
Link

FAQs

Read the most frequently asked questions about the Swoop® system.

click to read about Where to Find Swoop® - opens in new window
{disply_title}
Link

Where to Find Swoop®

Point-of-care neuroimaging near you.